Risk Factors Influencing Quality of Intraoperative Wake-up Test for Extremely Severe Scoliosis Surgery
1.Department of Anesthesiology,the Third People's Hospital of Chengdu,Southwest Jiaotong University
2.Center of Cardiac Surgery,Sichuan Academy of Medical Sciences & Sichuan Provincial-People’s Hospital
3.Department of Orthopedics,the Third People's Hospital of Chengdu,Southwest Jiao Tong University
摘要目的 探讨极重度脊柱侧凸矫形术中唤醒质量的影响因素。方法 收集2013年1月至2018年4月拟行脊柱矫形术的先天性极重度脊柱侧凸的513例患者临床资料。其中男性196例,女性317例;年龄13~34岁,平均(28.5±4.1)岁。患者术前主弯Cobb角平均为(137.5±26.8)°。根据唤醒质量将患者分为优良组及差组,采用单因素分析和多因素logistic回归分析分析可能影响患者术中唤醒质量的18项临床因素。结果 单因素分析显示,第1秒用力呼气容积(forced expiratory volume in one second,FEV-1)、第1秒用力呼气量占用力肺活量比值(ratio of forced expiratory volume in one second to forced vital capacity,FEV-1/FVC)、唤醒前体温、唤醒前动脉二氧化碳分压(arterial CO-2 partial pressure,PaCO-2)、唤醒前血红蛋白(hemoglobin,Hb)与极重度脊柱侧凸矫形术中唤醒质量有关(P<0.05)。多因素logistic回归分析显示,唤醒前体温(OR=1.973,95%CI:1.817~4.129,P<0.05)、唤醒前PaCO-2(OR=15.561,95%CI:6.278~33.368,P<0.05)、唤醒前Hb(OR=6.413,95%CI:3.460~14.653,P<0.05)是影响极重度脊柱侧凸矫形术中唤醒质量的独立危险因素。结论 极重度脊柱侧凸矫形术中唤醒质量与唤醒前体温、唤醒前PaCO-2、唤醒前Hb有关,做好围术期管理是提高术中唤醒质量的关键。
Abstract:Objective To investigate the risk factors influencing the quality of intraoperative wake-up test undergoing scoliosis surgery.Methods The clinical data of 513 patients with extremely severe scoliosis between January 2013 and April 2018 were reviewed.Among them,196 were male and 317 were female;age ranged from 13 to 34 years,with a mean of (28.5±4.1) years.The mean preoperative main curve Cobb angle of the patients was (137.5±26.8)°.A total of 18 potential factors associated with poor quality of intraoperative wake-up test were evaluated by univariate analysis and multivariate logistic regression analysis.Results The univariate analysis showed that forced expiratory volume in one second(FEV-1),ratio of forced expiratory volume in one second to forced vital capacity (FEV-1/FVC),body temperature,arterial CO-2 partial pressure(PaCO-2),hemoglobin(Hb) were significantly influenced the quality of intraoperative wake-up test (P<0.05).Multivariate logistic regression analysis showed that body temperature (OR=1.973,95%CI:1.817~4.129,P<0.05),PCO-2 (OR=15.561,95%CI:6.278~33.368,P<0.05),Hb (OR=6.413,95%CI:3.460~14.653,P<0.05) were independent risk factors for the quality of intraoperative wake-up test undergoing scoliosis surgery.Conclusion Body temperature,PaCO-2,Hb are independent risk factors for the quality of intraoperative wake-up test undergoing scoliosis surgery.
[1]Balsano M,Negri S.Natural course and classification of idiopathic scoliosis:A case-based approach[M]// Bernhard M,Michael R.Spine Surgery.Berlin:Springer,2019:141-148.
[2]Blussé O,Heleen J,Margreke J,et al.Population pharmacokinetic-pharmacodynamic model of propofol in adolescents undergoing scoliosis surgery with intraoperative wake-up test:a study using bispectral index and composite auditory evoked potentials as pharmacodynamic endpoints[J].BMC Anesthesiol,2019,19(1):15.
[3]杜晓宣,郑传东,李宏.脊柱外科麻醉学[M].广州:广东科技出版社,2018:324.
[4]Popko J,Kwiatkowski M,Galczyk M.Scoliosis:review of diagnosis and treatment[J].Polish J App Sci,2018,4(1):31-35.
[5]刘尚礼,李卫平,李远景,广东省青少年脊柱侧凸患病率调查报告[J].中国脊柱脊髓杂志,2002,12 (1):168-169.
[6]王彦辉,陈学明,袁鑫,北京市通州区中学生脊柱侧凸流行病学调查[J].中国脊柱脊髓杂志,2018,28(7):667-669.
[7]Zhao D,Liang YJ,Wang F,et al.Treatment goal for extremely severe scoliosis correction[J].Advances in Clinical Medicine,2018,8(3):312.
[8]Strike SA,Hassanzadeh H,Jain A,et al.Intraoperative neuromonitoring in pediatric and adult spine deformity surgery[J].Clin Spine Surg,2017,30(9):2380-2386.
[9]Ushirozako H,Yoshida G,Kobayashi S,et al.Impact of total propofol dose during spinal surgery:anesthetic fade on transcranial motor evoked potentials[J].J Neurosurg Spine,2019,30(5):705-713.
[10]Schwartz DM,Sestokas AK.Facilitated assessment of unconsciousness from morphologic changes in the bilateral posterior tibial nerve cortical somatosensory evoked potential under total intravenous propofol anesthesia during spine surgery[J].J Clin Monit Comput,2004,18(3):201-206.
[11]孔富姣,王锷,唐朝辉,等.不同麻醉方法用于神经外科术中唤醒的比较[J].临床麻醉学杂志,2017,33(5):499-500.
[12]Ushirozako H,Yoshida G,Kobayashi S,et al.Characteristics of false-positive alerts on transcranial motor evoked potential monitoring during pediatric scoliosis and adult spinal deformity surgery:an “anesthetic fade” phenomenon[J].J Neurosurgery Spine,2019,1(22):1-9.
[13]Ushirozako H,Yoshida G,Kobayashi S.et al.Severe outcomes of pediatric perioperative adverse events occurring in operating rooms compared to off‐site anesthetizing locations in the wake up safe database[J].Pediatr Anesth,2019,29(1):38-43.
[14]Shaw R,Skovrlj B,Cho SK.Association between age and complications in adult scoliosis surgery[J].Spine,2016,41(6):508-514.
[15]Helal SM,Abdelaziz AA,Dawoud AGE.Anesthetic considerations during intraoperative neurophysiological monitoring in spine surgery[J].Menoufia Medical Journal,2018,31(4):1187
[16]D Samartzis,Bow H,Cheung J,et al.Efficacy of postoperative pain management using continuous local anesthetic infusion at the iliac crest bone graft site in patients with adolescent idiopathic scoliosis:A parallel,double-blinded,randomized controlled pilot trial[J].Global Spine J,2015,6(3):220-228.
[17]Long LY,Tan YE,Sitaram R,et al.Systematic re-evaluation of intraoperative motor-evoked potential suppression in scoliosis surgery[J].Scoliosis Spinal Disorders,2018,13(1):12.
[18]Cao J,Li H,Song S,et al.Analysis of dexmedetomidine on the quality of awakening during neurosurgery[J].Translational neuroscience,2019,10(1):152-156
[19]Chen ZY,Dai N,Lin S,et al.Impact of dexmedetomidine on intraoperative wake-up tests in patients undergoing spinal surgery[J].J Peri Anesth Nurs,2018,33(4):448-452.