Abstract:Objective To investigate the cause of vertebral fracture after recent percutaneous kyphoplasty for vertebral osteoporosis vertebral compression fractures.Methods A retrospective analysis of related clinical data of 188 patients with PKP treatment who meet theinclusion criteria was performed.According to the clinical manifestation and imaging of thepatient,the patients were divided intogroup A(surgicalvertebral fracture,n=24) and group B (Nosurgical vertebral fracture,n=164).Follow-upafter the operationwasone year at lest.The records included the patient's age、gender、height、weight、body mass index (BMI)、bone mineral density、operation section、injection amount of bone cement、bone cement dispersion morphology、the distance that between bone cement and cranial endplates andcaudalendplates、wear the support time after surgery and whether to use a standardized antiosteoporosis treatment and other related factors,to explore the cause of postoperative surgical vertebral fracture.Results There was no significant difference between group A and group B,in terms of age、gender、height、weight、body mass index (BMI)、operation section、injection amount of bone cement and wear the support time(P>0.05).For postoperative management of patients with postoperative adherence to the treatment of osteoporosis,group A was not as good asto group B.Six months after surgery,the bone mineral density were(-2.46±0.700)、(-2.21±0.715)respectively.The difference was statistically significant(P<0.05).The final follow-up bone mineral density were (-2.37±0.896) and(-1.92±0.804)respectively.There was a significant difference between group A and group B(P<0.01).The shapes of bone cement in vertebral body were divided into masses and spongy.There were 15 cases and 58 caseswith mass-shapedbonecement,and 9 cases and 106 cases with the spongy-shapedbone cementin group A and group B respectively.The difference was statistically significant(χ2=6.490,P<0.05).3 day safter surgery,we measured the distance that between bone cement and caudal endplates.It were(3.38±0.744)mm in group A and(1.98±0.707)min group B.And the distance between bone cement and cranial endplates were(3.13±0.835)mm in group A and(1.82±0.475)min group B.The differences were statistical significance(P<0.05).Conclusion The refractures after PKP are caused by multiple factors.The important risk factors include bone cement shape、the distance between bone cement and cranial endplates andcaudalendplates and bone mineral density.
[1]唐明.单侧入路经皮椎体后凸成形术治疗骨质疏松性椎体压缩骨折[J].实用骨科杂志,2016,22(6):542-544.
[2]黄卫国,李玉民,海涌.PKP治疗骨质疏松性椎体压缩性骨折的中期临床疗效分析[J].实用骨科杂志,2015,21(2):105-109.
[3]黄江发,桑莉莉,谢雨舟,等.PVP/PKP术后非手术椎体再发骨折的相关因素分析[J].中国中医骨伤科杂志,2016,24(7):40-43.
[4]张斌,尚咏.经皮椎体后凸成形术后继发邻近椎体骨折的危险因素分析[J].临床骨科杂志,2014,17(3):249-252.
[5]李格,梅伟,刘沛霖,等.骨质疏松性椎体压缩骨折经皮椎体成形术后邻近椎体再骨折的危险因素探讨[J].中医正骨,2016,28(6):18-20.
[6]李俊青,刘纪恩,勾瑞恩,等.经皮穿刺椎体后凸成形术后邻近椎体骨折的危险因素[J].河南外科学杂志,2016,22(2):10-12.
[7]Kim YY,Rhyu.KWRe compression of vertebral body after balloon kyphoplasty for osteoporotic vertebral compression fracture[J].Eur Spine J,2010,19(11):1907-1912.
[8]唐政杰,侯宇,张亘瑷,等.椎体后凸成形术后再发骨折的相关危险因素分析[J].中国矫形外科杂志,2015,23(2):124-131.
[9]余博臣,张亮,高梁斌.PVP/PKP术后手术椎体再发骨折的研究进展[J].中国脊柱脊髓杂志,2012,22(2):183-185.
[10]Chen LH,Hsieh MK,Liao JC,et al.Repeated percutaneous vertebroplasty for refracture of cemented vertebrae[J].Arch Orthop Trauma Surg,2011,131(7):927-933.
[11]Lavelle WF,Cheney R.Recurrent fracture after vertebral kypho-plasty[J].Spine J,2006,6(5):488-493.
[12]Klazen CA,Venmans A,de Vries J,et al.Percutaneous vertebroplasty is not a risk factor for new osteoporotie compression fractures:resuhs from VERTOS Ⅱ[J].Am J Neuroradiol,2010,31(8):1447-1450.
[13]Heo DH,Chin DK,Yoon YS,et al.Recollapse of previous vertebral compression fracture after percutaneous vertebroplasty[J].Osteoporos Int,2009,20(3):473-480.
[14]Tanigawa N,Komemushi A,Kariya S,et al.Relationship between cement distribution pattern and new compression fracture after percutaneous vertebroplasty[J].AJR Am J Roentgenol,2007,189(6):348-352.
[15]Chevalier Y,Pahr D,Charlebois M,et al.Cement distribution,volume,and compliance in vertebroplasty:some answers from an anatomy-based nonlinear finite element study[J].Spine,2008,33(16):1722-1730.