Abstract:Objective To evaluate the three-dimensional biomechanic stability of a new fixable anterior cervical mesh in a corpectomy model.Methods We designed and produced the novel mesh.And Six fresh male cadaver cervical specimens were used.The intact,C5 corpectomy fixed with mesh and plate,C5 corpectomy fixed with fixable mesh were tested.range of motion of the fixed segments were measured under non-contact photographic recording system.Results The fixable mesh can provide enough stability,but not as stable as mesh-plate mode,especially in flexion movement.Conclusion The fixable mesh can provide enough stability after anterior cervical corpecomy.Although not as stable as mesh-plate,the new mode may be favor to fusion.
[1]Young WF.Cervical spondylotic myelopathy:a common cause of spinal cord dysfunction in older persons[J].Am Fam Physician,2000,62(5):1064-1070.
[2]Karadimas SK,Erwin WM,Ely CG,et al.Pathophysiology and natural history of cervical spondylotic myelopathy[J].Spine (Phila Pa 1976),2013,38(22 Suppl 1):S21-36.
[3]Andaluz N,Zuccarello M,Kuntz C.Long-term follow-up of cervical radiographic sagittal spinal alignment after 1-and 2-level cervical corpectomy for the treatment of spondylosis of the subaxial cervical spine causing radiculomyelopathy or myelopathy:a retrospective study[J].J Neurosurg Spine,2012,16(1):2-7.
[4]Hee HT,Majd ME,Holt RT,et al.Complications of multilevel cervical corpectomies and reconstruction with titanium cages and anterior plating[J].J Spinal Disord Tech,2003,16(1):1-8.
[5]Nunley PD,Jawahar A,Kerr EJ 3rd,et al.Choice of plate may affect outcomes for single versus multilevel ACDF:results of a prospective randomized single-blind trial[J].Spine J,2009,9(2):121-127.
[6]Schroeder GD,Kepler CK,Hollern DA,et al.The effect of dynamic versus static plating systems on fusion rates and complications in 1-level and/or 2-level anterior cervical discectomy and fusion:a systematic review[J].Clin Spine Surg,2017,30(1):20-26.
[7]Chen Y,Chen D,Guo Y,et al.Subsidence of titanium mesh cage:a study based on 300 cases[J].J Spinal Disord Tech,2008,21(7):489-492.
[8]Yan D,Wang Z,Deng S,et al.Anterior corpectomy and reconstruction with titanium mesh cage and dynamic cervical plate for cervical spondylotic myelopathy in elderly osteoporosis patients[J].Arch Orthop Trauma Surg,2011,131(10):1369-1374.
[9]张在恒,厉玉杰,王永峰,等.颈椎前路钢板与零切迹系统治疗多节段伴后凸畸形颈椎病[J].实用骨科杂志,2017,23(7):600-608.
[10]Karikari IO,Jain D,Owens TR,et al.Impact of subsidence on clinical outcomes and radiographic fusion rates in anterior cervical discectomy and fusion:a systematic review[J].J Spinal Disord Tech,2014,27(1):1-10.
[11]Luo J,Cao K,Huang S,et al.Comparison of anterior approach versus posterior approach for the treatment of multilevel cervical spondylotic myelopathy[J].Eur Spine J,2015,8(24):1621-1630.
[12]Kabir SM,Alabi J,Rezajooi K,et al.Anterior cervical corpectomy:review and comparison of results using titanium mesh cages and carbon fibre reinforced polymer cages[J].Br J Neurosurg,2010,24(5):542-526.
[13]吴增志,赖茂松,熊浩,等.ZeroP椎间融合术治疗颈椎间盘突出并脊髓损伤的疗效观察[J].实用骨科杂志,2017,23(4):363-365.
[14]Mackiewicz A,Banach M,Denisiewicz A,et al.Comparative studies of cervical spine anterior stabilization systems:finite element analysis[J].Clin Biomech,2016,32(2):72-79.