Abstract Objective To develop a novel puncture localization device and evaluate its application value in assisting puncture localization in lumbar intervertebral foramen surgery.Methods A right triangle can be constructed in the three-dimensional space of the lumbar spine,and the hypotenuse was that the ideal puncture path for the posterolateral approach.According to this principle,a puncture positioning device was developed to assist surgery.From June 2020 to April 2021,there were 64 patients diagnosed with single segment lumbar disc herniation and underwent percutaneous transforaminal surgery in the orthopedic department of Wuzhou Red Cross Hospital,including 34 males and 30 females.The age range was 22~79 years,with an average of (55.15±16.42) years old.Patients were randomly divided into a puncture positioning device group and a traditional group that completed puncture positioning with freehand technqiue under C-arm fluoroscopy.Among them,the device group had 34 cases and the traditional group had 30 cases.We compare the puncture frequency,puncture time,fluoroscopy frequency,visual analogue scale(VAS) pain score,Japanese Orthopaedic Association (JOA) score,and Oswestry Disability Index (ODI) of two groups of patients at specific times before and after surgery.Results The puncture frequency,puncture time,and fluoroscopy frequency of the positioning device group were all lower than those of the traditional group,with a statistically significant difference (P<0.05).The JOA score and ODI index of the two groups of patients improved significantly at 1 day and 6 months after surgery compared to before surgery (P<0.05);There was no statistically significant difference in VAS score,JOA score,and ODI index between the two groups (P>0.05).Conclusion Right triangle measurement can be used as a new preoperative design method.The application of this new puncture positioning device in lumbar intervertebral foramen endoscopic surgery can reduce the number and time of punctures,improve accuracy,and is particularly suitable for beginners.
|
|
Corresponding Authors:
Gan Xiutian
|
|
|
|
[1]Liu X,Yuan S,Tian Y,et al.Comparison of percutaneous endoscopic transforaminal discectomy,microendoscopic discectomy,and microdiscectomy for symptomatic lumbar disc herniation:minimum 2year follow-up results[J].Neurosurg Spine,2018,28(3):317-325.
[2]Ahn SS,Kim SH,Kim DV,el al.Comparison of outcomes ofperculaneous endoscopic lumbar discectomy and open lumbar microdiscectomy for young adults:A retrospective matched cohort study[J].World Neurosurg,2016(86):250-258.
[3]Mehren C,Wanke-Jellinek L.Posterior foraminotomy for lateral cervical disc herniation[J].Eur Spine J,2019,28(Suppl 1):1-2.
[4]Ao S,Wu J,Zheng W,et al.A novel largeledforaminoplasty device improves the efficacy and safety of foraminoplasty in pereulaneous endoscopic lumbar discectomy:Preliminary clinieal application of 70 ceases[J].World Neurosurg,2018(115),e263-e271.
[5]Wu R,Liao X,Xia H.Radiation exposure to the surgeon during ultrasound-assisted transforaminal percutaneous endoscopic lumbar discectomy:Aprospective study[J].World Neurosurg,2017,101(5):658-665.
[6]Fan G,Han R,Gu X,et al.Navigation improves the learning curve of transforamimal percutaneous endoscopic lumbar discectomy[J].Int Orthop,2017,41(2):323-332.
[7]田伟,陈伯华.腰椎间盘突出症诊疗指南[J]中华骨科学杂志,2020,40(8):477-487.
[8]Heider FC,Mayer HM.Surgical treatment of lumbar disc herniation[J].Oper Orthop Traumatol,2017,29(1):59-85.
[9]Schbert M,Hoogland T.Endoscopictransforaminalnucleotomy with foraminoplasty for lumbar disk herniation[J].Oper Orthop Traumatol,2005,17(6):641-661.
[10]白一冰.椎间孔镜BEIS技术操作规范[M].北京:人民卫生出版社,2015:83.
[11]李长青,周跃,王建,等.经皮椎间孔内窥镜下靶向穿刺椎间盘切除术治疗腰椎间盘突出症[J].中国脊柱脊髓杂志,2013,23(3):193-197.
[12]Ashley EA.Towards precision[J].Nat Rev Genet,2016,17(9):507-522.
[13]Collins FS,Varmus H.A new initiative on precision medicine[J].N Engl J Med,2015,372(9):793-795.
[14]Mahesha K.Percutaneous endoscopic lumbar discectomy results of first 100 cases[J].Indian J Orthop,2017,51(1):36-42.
[15]Zeng Y,Bao J,Su J,et al.Novel targeted puncture technique for percutaneous transforaminal endoscopic lumbar discectomy reduces X-ray exposure[J].ExpTher Med,2017,14(4):2960-2968.
[16]Choi G,ModiHN,Prada N,et al.Clinical results of XMR-assisted percutaneoustransforaminal endoscopic lumbar discectomy[J].Orthop Surg Res,2013,8(1):14.
[17]Liu YB,Wang Y,Chen ZQ,et al.Volume navigation with fusion of real-time ultrasound and ct images to guide posterolateral transforaminal puncture in percutaneous endoscopic lumbar discectomy[J].Pain Physician,2018,21(3):E265-E278.
[18]刘维克,夏乐,杨同岗,等.骨科手术机器人在个体化椎间孔镜穿刺导向中的应用[J].颈腰痛杂志,2020,41(4):389-391.
[19]Ajiboye RM,Koltsov JCB,Karamian B,etal.Computerassisted surgical navigation is associated wih an increased risk of neurological complications:A review of 67,264 posterolateral lumbar fusion cases[J].Spine Surg,2019,5(4):457-465.
[20]Fomekong E,Pierrard J,Raftopoulos C.Comparative cohort study of percutaneous pedicle screw implantation without versus with navigation in patients undergoing surgery for degenerative lumbar disc disease[J].World Neurosurg,2018(111):e410-e417.
[21]Luenam S,Kosiyatrakul A,Hansudewechakul C,el al.The patient-specific implant created with 3D printing technology in treatment of the irreparable radial head in chronic persistent elbow instability[J].Case Rep Orthop,2018(2018):9272075. |
[1] |
. [J]. sygkzz, 2022, 28(5): 436-441. |
|
|
|